Open actionable advisories and recorded vendor fixes. This public package view has no inventory attached and cannot establish whether your deployment is affected. A vendor fix never resolves your finding; verify your installed version and the source guidance.
Open advisories
6 actionable advisories, newest first. Withdrawn advisories and news are excluded. Coverage is partial.
Impact Wasmtime's code generator, Cranelift, has a bug on x8664 targets where address-mode computation mistakenly would calculate a 35-bit effective address instead of WebAssembly's defined 33-bit effective address. This bug means that, with default codegen settings, a wasm-controlled load/store operation could read/write addresses up to 35 bits away from the base of linear memory. Wasmtime's default sandbox settings provide up to 6G of protection from the base of linear memory to guarantee that any memory access in that range will be semantically correct. Due to this bug, however, addresses up to 0xffffffff 8 + 0x7ffffffc = 36507222004 = ~34G bytes away from the base of linear memory are possible from guest code. This means that the virtual memory 6G away from the base of linear memory up to ~34G away can be read/written by a malicious module. This out of bounds read/write is not semantically correct and poses a threat as an arbitrary read/write within ~34G of linear memory away…
Recommended action: Upgrade to 0.93.1, 0.92.1 or 0.91.1 by release line, then redeploy and verify.A vendor fix does not resolve your finding until you verify it in your own systems.
Impact Wasmtime's code generation backend, Cranelift, has a bug on x8664 platforms for the WebAssembly i8x16.select instruction which will produce the wrong results when the same operand is provided to the instruction and some of the selected indices are greater than 16. There is an off-by-one error in the calculation of the mask to the pshufb instruction which causes incorrect results to be returned if lanes are selected from the second vector. The impact of this miscompilation is that the WebAssembly instruction can produce incorrect results for the i8x16.select instruction. This should have no effect on embedders and does not represent a sandbox escape, for example. Guest programs, however, may behave unexpectedly due to the incorrect result of this instruction. In extreme cases if a guest program is handling untrusted input then the guest program may deviate from its intended execution, for example calling an imported host function with different arguments than intended. This…
Recommended action: Upgrade to 0.93.1, 0.92.1 or 0.91.1 by release line, then redeploy and verify.A vendor fix does not resolve your finding until you verify it in your own systems.
Impact There was a bug in Wasmtime's code generator, Cranelift, for AArch64 targets where constant divisors could result in incorrect division results at runtime. The translation rules for constants did not take into account whether sign- or zero-extension should happen, which resulted in an incorrect value being placed into a register when a division was encountered. For example, a constant 32-bit unsigned divisor of 0xfffffffe would be incorrectly sign-extended to 64-bits to 0xfffffffffffffffe. Any kind of division of operands smaller than 64 bits is implemented with a 64-bit division instruction which would then result in an incorrect result because the divisor was larger than expected. The impact of this bug is that programs executing within the WebAssembly sandbox would not behave according to the WebAssembly specification. This means that it is hypothetically possible for execution within the sandbox to go awry and WebAssembly programs could produce unexpected results. This…
Recommended action: Upgrade to 0.85.2 or later, then redeploy and verify.A vendor fix does not resolve your finding until you verify it in your own systems.
There is a bug in Wasmtime's code generator, Cranelift, where functions using reference types may be incorrectly missing metadata required for runtime garbage collection (GC). This means that if a GC happens at runtime then the collector will mistakenly think some Wasm stack frames do not have live references to garbage collected values and therefore reclaim and deallocate them. The function can then subsequently continue to use the values, leading later to use-after-free bugs. This bug was introduced in Cranelift's migration to the regalloc2 register allocator in the Wasmtime 0.37.0 release on 2022-05-20. This bug has been patched and users should upgrade to Wasmtime version 0.38.2. Mitigations for this issue can be achieved by doing one of: Disabling the reference types proposal by passing false to wasmtime::Config::wasmreferencetypes. Downgrading to Wasmtime 0.36.0 or prior.
Recommended action: Upgrade to 0.85.2 or later, then redeploy and verify.A vendor fix does not resolve your finding until you verify it in your own systems.
Impact Wasmtime's implementation of the SIMD proposal for WebAssembly on x8664 contained two distinct bugs in the instruction lowerings implemented in Cranelift. The aarch64 implementation of the simd proposal is not affected. The bugs were presented in the i8x16.swizzle and select WebAssembly instructions. The select instruction is only affected when the inputs are of v128 type. The correspondingly affected Cranelift instructions were swizzle and select. The swizzle instruction lowering in Cranelift erroneously overwrote the mask input register which could corrupt a constant value, for example. This means that future uses of the same constant may see a different value than the constant itself. The select instruction lowering in Cranelift wasn't correctly implemented for vector types that are 128-bits wide. When the condition was 0 the wrong instruction was used to move the correct input to the output of the instruction meaning that only the low 32 bits were moved and the upper 96…
Recommended action: Upgrade to 0.85.1 or later, then redeploy and verify.A vendor fix does not resolve your finding until you verify it in your own systems.
There is a bug in 0.73.0 of the Cranelift x64 backend that can create a scenario that could result in a potential sandbox escape in a WebAssembly module. Users of versions 0.73.0 of Cranelift should upgrade to either 0.73.1 or 0.74 to remediate this vulnerability. Users of Cranelift prior to 0.73.0 should update to 0.73.1 or 0.74 if they were not using the old default backend. Description This bug was introduced in the new backend on 2020-09-08 and first included in a release on 2020-09-30, but the new backend was not the default prior to 0.73.0. The recently-released version 0.73.0 with default settings, and prior versions with an explicit build flag to select the new backend, are vulnerable. The bug in question performs a sign-extend instead of a zero-extend on a value loaded from the stack, under a specific set of circumstances. If those circumstances occur, the bug could allow access to memory addresses up to 2GiB before the start of the heap allocated for the WebAssembly module.…
Recommended action: Upgrade to 0.73.1 or later, then redeploy and verify.A vendor fix does not resolve your finding until you verify it in your own systems.